A bare plan in.
Measured areas out.Gross internal area and net internal area to the RICS Code, from a bare DXF

Gross internal area (GIA) is measured to the internal faces of the perimeter walls; net internal area (NIA) is what remains usable after deductions such as WCs, plant rooms and structural walls. In this recorded run a bare existing plan went in as a DXF, with six openings and no doors. ArchX drew the doors, labelled every room with its area and measured a GIA of 70.55 m² and a provisional NIA of 55.56 m² to the RICS Code of Measuring Practice. It took 5 minutes 23 seconds.

The run in the video used the England edition of ArchX, with English terms, rules and pounds. In Ireland, ArchX works from the project documents and the local sources you open.

What goes in.

The existing ground floor of Unit 3 as a DXF, with the same survey as a PDF. The request: doors in all the openings, GIA and NIA to the RICS Code, room labels with areas, an editable DXF and an A3 sheet at 1:50 with an area schedule.

What ArchX does.

  1. 01

    Draws the doors

    Six single-swing doors: one from outside at 1,000 mm, five inside at 900 mm, each in a door schedule with its hinge side.

  2. 02

    Measures the GIA

    To the internal faces of the perimeter walls: 9.515 × 7.415 m, reported as 70.55 m².

  3. 03

    Deducts for the NIA

    Less the WC, the plant room, structural walls and thresholds: 55.56 m². A second sum, room areas plus one non-structural partition, gives the same figure.

  4. 04

    Labels the rooms

    Every room gets its number, name and area. The open porch, 4.05 m², stays outside GIA and NIA.

What comes back.

  • The plan as an editable DXF, with doors, room outlines and labels on new layers
  • An A3 sheet at 1:50 as PDF, with door schedule, area schedule and the reconciliation from GIA to NIA
  • The schedules as an Excel spreadsheet, the room areas as a CSV file

The figures from the run.

5 min 23 s

working time for one request

70.55 m²

gross internal area

55.56 m²

net internal area, provisional

6

doors added

What stays with you.

The NIA is provisional, and the sheet says why: it assumes the 215 mm walls are structural and the 100 mm partitions not, that the entrance hall belongs to Unit 3 alone and that no floor has headroom below 1.5 m. Door widths are the drawn openings, and the handing is to be confirmed. North is not recorded.

Where the video comes from.

A recorded run of the ArchX England edition on 1 November 2026 (blind-test task gb-03-plan-doors-areas), one request. The project is a test project. The video shows this run, re-staged and sped up.

What the video says.

The video has music and no voice. This is the text that appears on screen, in the order of the video.

  1. A bare plan in. Measured areas out.
  2. An existing ground floor, as a DXF
  3. Existing ground floor of Unit 3 as DXF. Add doors to all the door openings (single swing), measure GIA and NIA to the RICS Code, add room labels with areas. Editable DXF plus A3 1:50 sheet.
  4. Reads the floor plan. Six openings, no doors. The existing DXF: walls, windows and room names.
  5. Builds the floor plan. Six single-swing doors. One from outside at 1,000 mm, five inside at 900 mm.
  6. Labels the rooms with areas. Every room labelled with its area. Floor areas within the wall faces.
  7. Measures the gross internal area. GIA 70.55 m². To the internal faces of the perimeter walls, RICS sixth edition.
  8. Deducts for the net internal area. NIA 55.56 m², provisional. Less WC, plant room, structural walls and thresholds.
  9. Worked for 5 min 23 s
  10. GIA: 70.55 m². Provisional NIA: 55.56 m², measured from the existing DXF using the RICS sixth-edition basis. Six single-swing doors are added. The sheet gives the full reconciliation.
  11. The A3 sheet at 1:50, every room labelled. GIA 70.55 m², NIA 55.56 m², room by room. From GIA to NIA, every deduction shown. The area schedule in Excel. An editable DXF, doors and labels on layers. Sheet, DXF and spreadsheet from one request.
  12. 5 minutes. From a bare plan to measured areas. Real run: 5 min 23 s, one request. Test project.
  13. Real ArchX run, re-staged and sped up. Test project.

Which program it needs.

The run started from a DXF drawing. Revit, Vectorworks, AutoCAD, Archicad and Allplan all save drawings as DXF, so a practice in any of them gives ArchX the same kind of file. The video itself shows none of these programs. ArchX does not open DWG on its own: save the drawing as DXF. The drawings come back as DXF, ready to import into Revit, Vectorworks, AutoCAD, Archicad and Allplan.

Explained briefly.

Gross internal area (GIA)
The floor area measured to the internal faces of the perimeter walls. Here 9.515 × 7.415 m, reported as 70.55 m², with the open porch of 4.05 m² left outside.
Net internal area (NIA)
The usable area left after deductions. Here the WC, the plant room, structural walls and thresholds come off, giving 55.56 m², provisional because the sheet assumes which walls are structural.
RICS Code of Measuring Practice
The measuring rules of the Royal Institution of Chartered Surveyors in which GIA and NIA are defined. The run used the sixth edition, as the request asked, and the sheet states the basis.

Asked briefly.

How do you measure GIA?

To the internal faces of the perimeter walls, as the RICS Code of Measuring Practice sets out. In this run that gave 9.515 × 7.415 m, reported as 70.55 m²; the open porch stays outside.

What is the difference between gross and net internal area?

GIA is the whole area inside the perimeter walls, NIA the usable part of it. Here the WC (5.10 m²), the plant room (6.00 m²), structural walls and thresholds came off 70.55 m² of GIA, leaving 55.56 m² of NIA.

Which measuring basis does ArchX use?

In this run the RICS Code of Measuring Practice, sixth edition, as the request asked. The sheet states the basis and every deduction.

Does it change the existing drawing?

No. The existing geometry stays as it was; the doors, room outlines and labels sit on new layers.

Does this work if we draw in Revit, Vectorworks or AutoCAD?

Yes. The run started from a DXF drawing. Revit, Vectorworks, AutoCAD, Archicad and Allplan all save drawings as DXF, so a practice in any of them gives ArchX the same kind of file. The video itself shows none of these programs. ArchX does not open DWG on its own: save the drawing as DXF. The drawings come back as DXF, ready to import into Revit, Vectorworks, AutoCAD, Archicad and Allplan.

You have seen the video.
Now try it on your files.

Download ArchX for Mac or Windows, open a project folder and give it the same task. 7 days free, without payment details.