Archicad model in.
Quantities out.Archicad quantity takeoff, FAR and lot coverage, and a fire rating on nine walls
An Archicad quantity takeoff counts and measures the modelled elements, such as walls, windows, doors and finishes, straight from the model. In this run three plain requests went to ArchX, with a test project open in Archicad 28: the key figures, a takeoff by UniFormat and a fire rating on every wall. It returned 1,162.5 SF gross floor area, FAR 0.194 and 19.4% lot coverage, a takeoff from the model, and a 1-hour rating on all nine walls after one approval, in 3 minutes 47 seconds.
The run in the video used the U.S. edition of ArchX, with U.S. terms, rules and units. In New Zealand, ArchX works from the project documents and the local sources you open.
What goes in.
No files: an untitled test project was open in Archicad 28 USA, a ground floor with six rooms. The first request was ‘What are the gross floor area, FAR and lot coverage? The lot is 6,000 square feet.’ Two follow-ups asked for a takeoff by UniFormat and for every wall to be rated 1 hour.
What ArchX does.
- 01
Works out the key figures
Gross floor area from the ground-floor slabs, with the arithmetic shown: FAR 1,162.5 ÷ 6,000 = 0.194. ArchX calls them model figures before local zoning exclusions.
- 02
Takes off quantities by UniFormat
7 exterior windows, 1 exterior door, 5 interior doors, 1,013.03 SF of exterior walls and 717.12 SF of partitions. Wall areas are net of openings; finishes come from the six rooms.
- 03
Reads the wall ratings
The five 5-inch partitions have no fire rating; the four exterior walls are rated 2 hours.
- 04
Changes nine walls, after approval
A card names the change and waits. Then ArchX sets all nine walls to 1 hour, reads them back and leaves them selected in Archicad.
What comes back.
- The key figures with their arithmetic, in the conversation and as an Excel file
- The UniFormat takeoff as a table and as an editable Excel file
- Nine walls rated 1 hour, in the model itself
The figures from the run.
working time for three requests, approval included
gross floor area, FAR 0.194 on a 6,000 SF lot
set to 1 hour: 5 had no rating, 4 had 2 hours
What stays with you.
The takeoff covers modelled elements only, without unmodelled work or waste, and the slab’s UniFormat code is marked provisional. The fire rating is a property in the model: ArchX said plainly that the wall assemblies were not verified for fire resistance.
Where the video comes from.
An acceptance run on 1 November 2026 with a developer build of ArchX in U.S. English and Archicad 28 USA on a Windows PC, in an untitled test project without client data. The video shows the first three requests of the conversation, re-staged and sped up.
What the video says.
The video has music and no voice. This is the text that appears on screen, in the order of the video.
- Archicad model in. Quantities out.
- The model, open in Archicad 28
- One request. Archicad is open beside it.
- What are the gross floor area, FAR and lot coverage? The lot is 6,000 square feet.
- Reads the open Archicad model. The open model, read live. Ground floor: 9 walls, 7 windows, 6 doors, 6 rooms.
- Calculates FAR and lot coverage. FAR 0.194, lot coverage 19.4%. 1,162.5 SF gross floor area on a 6,000 SF lot.
- Give me the quantity takeoff from the model by UniFormat.
- Takes off quantities by UniFormat. The takeoff, by UniFormat. 7 windows, 6 doors, partitions and finishes in SF.
- Which walls have no fire rating yet? Make every wall 1-hour rated.
- Reads the wall properties. 5 walls unrated, 4 at 2 hours. Five 5-inch partitions have no rating; the exterior walls have 2 hours.
- Asks before it changes the model. A card to approve first. It says what will change and waits for your approval.
- Changes the walls, reads them back. All 9 walls now rated 1 hour. Verified in the model; the assemblies were not checked.
- Worked for 3 min 47 s
- All 9 walls now have “Fire Resistance Rating” set to “1 hour”, verified after the change. The five interior partitions previously had no rating; the four exterior walls changed from 2 hours to 1 hour.
- Nine walls changed, selected in Archicad
- The takeoff by UniFormat, from the model
- Finish areas, taken from six rooms
- FAR and lot coverage, with the math
- Figures and takeoff also as Excel files
- 4 minutes. Key figures, a takeoff and a change to nine walls. Real run: 3 min 47 s for three requests, approval included.
- Real ArchX run, re-staged and sped up. Test project in Archicad 28.
Which program it needs.
This run worked inside the open Archicad model, with no file exported. Of the CAD programs, only Archicad is shown on video with ArchX working in the open model. A practice in Revit, Vectorworks, AutoCAD, Allplan or SketchUp gives ArchX its drawings as PDF or DXF and its models as IFC instead; the videos that start from such files are listed on the page for each program.
Explained briefly.
- UniFormat
- The element classification the takeoff is sorted by. Here the slab is marked provisional under B1010; A1030 Slab on Grade applies if ground support is confirmed.
- FAR (floor area ratio)
- Gross floor area divided by lot area: here 1,162.5 ÷ 6,000 = 0.194. ArchX calls it a model figure before local zoning exclusions.
- Lot coverage
- The share of the lot the building covers: here 1,162.5 ÷ 6,000 × 100 = 19.4%, with the footprint approximated.
Asked briefly.
Can I get a quantity takeoff from Archicad into Excel?
In this run, yes: the UniFormat takeoff came as a table in the conversation and as an editable Excel file, with wall areas net of openings and finishes from the six rooms.
What does the takeoff include?
Modelled elements only: 7 exterior windows, 1 exterior door, 5 interior doors, 1,013.03 SF of exterior walls, 717.12 SF of partitions and the finishes. Unmodelled work and waste are not in it.
Can ArchX undo the change?
Only partly, in this run. Asked to undo it, ArchX put the four exterior walls back to 2 hours but could not clear the rating on the five partitions, which had none before; its undo card said so and pointed to Archicad’s Edit › Undo. The video leaves that request out.
Are these the figures for the zoning check?
They are model figures before local zoning exclusions, with the footprint approximated, and projections and overhangs may change the coverage. Applying the local rules is your step.
Does this work if we draw in Revit, Vectorworks or AutoCAD?
Not as shown here: this video works inside Archicad. This run worked inside the open Archicad model, with no file exported. Of the CAD programs, only Archicad is shown on video with ArchX working in the open model. A practice in Revit, Vectorworks, AutoCAD, Allplan or SketchUp gives ArchX its drawings as PDF or DXF and its models as IFC instead; the videos that start from such files are listed on the page for each program.
The same task on your desk.
You have seen the video.
Now try it on your files.
Download ArchX for Mac or Windows, open a project folder and give it the same task. 7 days free, without payment details.