Seven drawings in.
Planning answer out.Permitted development check of a rear extension, with the 45-degree rule drawn

A permitted development check tests a house extension against each Class A limit, such as depth and eaves height near the boundary, to show whether a planning application is needed. In this recorded run seven drawings of a rear extension went in, with the site notes and the brief. ArchX checked the limits one by one: a householder application appears to be needed. The extension is 4.00 m deep against a 3 m limit, and its eaves are 3.075 m high within 2 m of the boundary, against 3 m. 10 minutes 33 seconds.

The run in the video used the England edition of ArchX, with English terms, rules and pounds. In Australia, ArchX works from the project documents and the local sources you open.

What goes in.

The drawing set for 14 Larch Walk: location and block plan, existing and proposed plans and elevations, and the proposed section. The request: the key dimensions with their source, a condition-by-condition answer on permitted development, a check against the council’s design guidance and the 45-degree check drawn on the plan.

What ArchX does.

  1. 01

    Reads the site notes

    The house is in a conservation area, so the larger-extension prior approval route is ruled out.

  2. 02

    Measures the depth

    4.00 m beyond the original rear wall. The 3.70 m on the plan is the internal depth, not the one that counts.

  3. 03

    Measures the eaves

    To the roof surface, not the parapet: 3.075 m, 75 mm over. The parapet is 3.10 m on plan and elevations but 3.30 m in the section, so the drawings need coordinating.

  4. 04

    Draws the 45-degree check

    The extension crosses the line to the neighbour’s kitchen window by 2.50 m on the plan, and the test fails in elevation too.

What comes back.

  • Permitted development assessment as PDF and Word, five pages, limit by limit with measured value and source drawing
  • Design guidance check as PDF and Word, two pages
  • Measurements and 45-degree checks as PDF, four pages, marked on plan and elevation

The figures from the run.

10 min 33 s

working time for one request

4.00 m

depth, against a limit of 3 m

3.075 m

eaves within 2 m of the boundary, against 3 m

2.50 m

beyond the 45-degree line on the plan

What stays with you.

Article 4 directions and the conditions of earlier permissions are marked as not yet confirmed. The neighbour’s window levels need a survey, and the 45-degree test is a screening guide, not a daylight assessment. The document says it is not a council decision: you check it, the council decides.

Where the video comes from.

A recorded run of the ArchX England edition on 12 October 2026 (test job S1, first request). The project is a test project. The video shows this run, re-staged and sped up.

What the video says.

The video has music and no voice. This is the text that appears on screen, in the order of the video.

  1. Seven drawings in. Planning answer out.
  2. Seven drawings, site notes and brief
  3. Rear extension at 14 Larch Walk. Tell me whether this could go ahead as permitted development or needs planning permission, condition by condition. Draw the 45-degree check on the plan.
  4. Reviews project files. Seven drawings read. Location and block plan, plans, elevations, section.
  5. Reads the site check notes. In a conservation area. So the larger-extension prior approval route is ruled out.
  6. Measures on the drawing. 4.00 m deep, limit 3 m. LW-200: measured beyond the original rear wall.
  7. Looks at part of the drawing. Eaves 3.075 m, 75 mm over. LW-220: to the roof surface, not the parapet. Limit 3 m at the boundary.
  8. Draws the 45° check on the plan. The 45° check, on the plan. From the end of the extension back to No. 12’s kitchen window.
  9. Worked for 10 min 33 s
  10. The current scheme appears to require a householder planning application. Its 4.00 m depth exceeds the 3.00 m limit, and the measured 3.075 m eaves exceed the 3.00 m boundary limit.
  11. Not within Class A: two limits exceeded. Depth 4.00 m against a 3 m limit. Eaves 3.075 m within 2 m of the boundary. The 45° line to No. 12, crossed by 2.50 m. The 45° test fails in elevation too. Assessment, guidance check, marked drawings.
  12. 11 minutes. From seven drawings to a planning answer. Real run: 10 min 33 s, one request. Test project.
  13. Real ArchX run, re-staged and sped up. Test project.

Which program it needs.

The run started from drawings as PDF. Revit, Vectorworks, AutoCAD, Archicad, Allplan and SketchUp all print drawings to PDF, so a practice in any of them gives ArchX the same kind of file. The video itself shows none of these programs.

Explained briefly.

Permitted development (Class A)
In England, the right to extend a house without a planning application within set limits; Class A covers enlargements such as this rear extension. Here the depth limit is 3 m, and within 2 m of the boundary the eaves limit is 3 m.
45-degree rule
A screening guide in the council’s design guidance for an extension’s effect on a neighbour’s window. Here the 45-degree line to No. 12’s kitchen window is crossed by 2.50 m on the plan; it is not a daylight assessment.
Householder application
The planning application for works to a house that permitted development does not cover. The assessment names it as the likely route here, with a fee of £548 and eight weeks to decide.

Asked briefly.

Do I need planning permission for a rear extension?

For this test scheme, yes: the assessment says a householder application appears to be needed, because the extension is 4.00 m deep against a 3 m limit and its eaves are 3.075 m within 2 m of the boundary, against 3 m.

How is the 45-degree rule checked?

On a marked copy of the proposed plan, ArchX drew the 45-degree line back to the neighbour’s kitchen window: the extension crosses it by 2.50 m. In elevation the test fails at either parapet height.

What would bring it within permitted development?

The assessment says: no deeper than 3 m, and eaves no higher than 3 m or the extension more than 2 m from the boundary. A depth of 3 m alone would still cross the 45-degree line.

What is the next step?

The assessment names a householder application as the likely route, with a fee of £548 and a statutory determination period of eight weeks.

Does this work if we draw in Revit, Vectorworks or AutoCAD?

Yes. The run started from drawings as PDF. Revit, Vectorworks, AutoCAD, Archicad, Allplan and SketchUp all print drawings to PDF, so a practice in any of them gives ArchX the same kind of file. The video itself shows none of these programs.

You have seen the video.
Now try it on your files.

Download ArchX for Mac or Windows, open a project folder and give it the same task. 7 days free, without payment details.