One address in.
Three options out.Zoning analysis and massing options for a Dallas lot, from the address alone

A massing study tests how much building the zoning limits allow on a site, as simple volumes with gross area and unit count, before anyone draws. In this recorded run a client wanted to buy a lot in Dallas, TX, and asked what could be built there. From the address alone, ArchX read public sources and the Dallas Development Code and returned three massing options as a client PDF and a spreadsheet. It recommends 12 one-bedroom homes at 11,700 gross SF if the client accepts no on-site parking, after 16 minutes 12 seconds of work.

The run in the video used the U.S. edition of ArchX, with U.S. terms, rules and units. In Ireland, ArchX works from the project documents and the local sources you open.

What goes in.

No drawings and no files: one message with the address, asking for the zoning limits and two or three massing options with gross area and unit count, as a PDF for the client meeting and a spreadsheet.

What ArchX does.

  1. 01

    Checks the parcel records

    The appraisal record gives 50 × 256 feet and 12,800 SF. The city’s GIS parcel is larger; ArchX credits no extra area.

  2. 02

    Reads the zoning code

    MF-2(A): 36 feet in height, 60% coverage, yards of 15, 10 and 15 feet, each with its code section. No car parking is required for 20 homes or fewer.

  3. 03

    Counts homes from the land

    At 800 SF of land per studio and 1,000 SF per one-bedroom home, the lot allows at most 16 studios or 12 one-bedroom homes.

  4. 04

    Steps the volumes down

    The footprint inside the yards is 6,780 SF. As a conservative assumption, ArchX treats the rear boundary as the start of a residential height slope and steps the taller options down towards it. Three options result: 6, 12 or 16 homes.

What comes back.

  • Client feasibility study as PDF, six pages: zoning limits with code sections, the three options on the lot, what limits the yield, what to settle before purchase, and the sources
  • The massing options as an Excel spreadsheet with formulas
  • A draft study in Word, a second workbook, a volume study and the research records

The figures from the run.

16 min 12 s

working time for one request

12,800 SF

lot area used, from the appraisal record

11,700 SF

gross area of the recommended option, with no on-site parking

What stays with you.

The study calls itself preliminary and names what it did not review: survey, title, plat, the seller’s plans and a City permit file. Whether the rear height slope applies is for the City to determine, and at the listing’s 50 × 255 feet the studio count drops to 15. You test the options and decide what goes to the client.

Where the video comes from.

A recorded run of the ArchX U.S. edition on 7 November 2026 (test job us-zoning-feasibility), shown re-staged and sped up. The lot is real and the study uses public sources; the client, the request and the practice are invented, and the address is covered.

What the video says.

The video has music and no voice. This is the text that appears on screen, in the order of the video.

  1. One address in. Three options out.
  2. One address in Dallas, TX. No drawings.
  3. The client's question, typed into ArchX
  4. A client is looking at buying a lot in Dallas, TX. What can we build there? Work out the zoning limits and two or three massing options with gross area and unit count. We need a PDF and a spreadsheet.
  5. Checks the official parcel records. 12,800 SF, 50 × 256 feet. The city's GIS area is larger; no extra area is credited.
  6. Reads the Dallas Development Code. MF-2(A): 36 feet, 60% coverage. Yards of 15, 10 and 15 feet, each limit with its code section.
  7. Counts homes from the land area. 16 studios or 12 one-bedrooms. The code requires 800 SF of land per studio, 1,000 per one-bedroom.
  8. Studies the zoning envelope. 6,780 SF of footprint inside the yards. Three full floors would give 20,340 SF, but that ignores the rear slope.
  9. Compares massing options. Three options: 6, 12 or 16 homes. Stepped down toward the rear, up to 11,700 gross SF.
  10. Writes the PDF and the spreadsheet. A PDF for the client meeting. Six pages, and a spreadsheet with the numbers.
  11. Worked for 16 min 12 s
  12. I recommend advancing the 12-unit option (11,700 SF), provided the client accepts zero on-site parking. The site maps MF-2(A): 36 feet in height, 60% coverage, yards of 15, 10 and 15 feet.
  13. The client PDF: what can be built here
  14. B: 12 homes, 11,700 SF, no car parking
  15. The third floor stops 121 feet from the rear
  16. What limits the yield: the rear height slope
  17. The spreadsheet: areas and homes per option
  18. Six pages for the client, plus the numbers
  19. 16 minutes. From one address to three massing options. Real run: 16 min 12 s. 12 homes recommended, 11,700 gross SF.
  20. Real ArchX run, re-staged and sped up. Real Dallas lot, address covered.

Which program it needs.

No CAD file goes in: the input is an address. It makes no difference whether the practice draws in Revit, Vectorworks, AutoCAD, Archicad, Allplan or SketchUp.

Explained briefly.

Zoning analysis
Reading the zoning code for a lot: district, height, coverage, yards and density, each with its code section. Here MF-2(A) in the Dallas Development Code: 36 feet, 60% coverage, yards of 15, 10 and 15 feet.
Buildable area
The footprint left inside the yards: here 6,780 SF on a 12,800 SF lot. Three full floors would give 20,340 SF, but the rear height slope cuts that down.
Height slope
A limit that lowers the permitted height towards a neighbouring residential district. ArchX treats the rear boundary as its start, as a conservative assumption; whether it applies is for the City to determine.

Asked briefly.

What can be built on this lot?

The study answers with three options: 6, 12 or 16 homes, stepped down towards the rear, up to 11,700 gross SF. The land per home caps the count at 16 studios or 12 one-bedroom homes, and the study names the rear height slope as what limits the yield.

Why the 12-home option?

The study gives two reasons: an average home of 780 SF net leaves 800 SF to spare in the land allowance, and the third floor stops 121 feet from the rear, where the height slope asks for 102 feet. If parking is essential, the study says to test option A first.

Did ArchX need drawings?

Not in this run. It worked from the address and public sources, among them the appraisal record, the city’s GIS layers and the code.

Does this work if we draw in Revit, Vectorworks or AutoCAD?

Yes. No CAD file goes in: the input is an address. It makes no difference whether the practice draws in Revit, Vectorworks, AutoCAD, Archicad, Allplan or SketchUp.

You have seen the video.
Now try it on your files.

Download ArchX for Mac or Windows, open a project folder and give it the same task. 7 days free, without payment details.