ArchX works
in Archicad.

Say what you need in your own words. ArchX reads your model, takes off areas and quantities and builds a whole house, from the shell and the roof up to a sheet at scale. It checks every result in the model and tells you how to undo it. For Archicad 28, 29 and 30 on Mac and Windows.

Living717.51 SFH 9′-0″32′-0″24′-0″N

What ArchX does in Archicad.

ArchX connects to Archicad on your computer and works in the open project. You say what you need, as you would to a colleague.

Read

Knows what is open.

Project, stories, working units and your selection: ArchX reads the model before it does anything.

Quantities

Areas and quantities from the model.

Rooms, areas, wall volumes and the number of windows and doors, per story and with units, straight from Archicad. Plus FAR, lot coverage and a takeoff by UniFormat as a spreadsheet.

Build

One sentence, new elements.

Walls, slabs, roofs, doors, windows, rooms and furniture with your dimensions and materials, on the right story, up to the drawing sheet at scale.

Change

Thicker, taller, kept in step.

Change wall thickness and height, keep doors in place, update the rooms, set one property on every wall at once. ArchX then reads every changed element back.

Undo

One sentence takes it back.

“Undo that last change” removes what ArchX built last and puts changed properties back to their earlier value. Archicad’s own Undo brings back a value that was empty before, deleted elements and other changes.

Show

The result in view.

ArchX highlights, selects and zooms Archicad to what it built or found.

Set up

Sets itself up.

If the connection to Archicad is missing, ArchX downloads it, checks it and installs it, on Windows even without administrator rights. You confirm once and restart Archicad.

Teamwork

Reserves before it changes.

In a Teamwork project, ArchX reserves the elements it changes. If someone else holds them, it stops and tells you who.

Title blocks filled in. Plus a sheet list.

Say what goes in the title blocks. ArchX reads the sheets of the Layout Book as Archicad draws them; above 60 it works the title block out itself. It names the empty fields and asks for what is missing, fills them in on every sheet, reads them back and saves the list as an Excel file.

Sheet index guide →
  1. You

    Fill in the title blocks for the permit set: owner Example Holdings LLC, status Permit Set, drawn by TG, and give me the sheet index.

    ArchX · 3 min 25 s

    Created the 8-sheet index showing the existing title blocks. No changes were applied: Archicad could no longer verify the untitled project’s identity. The template also lacks a visible owner field. Should I apply your entries to the currently open untitled Archicad 29 project?

  2. You

    The project is Example Duplex, 12 Example Street, Dallas, TX 75201. The architect is Example Architects LLC, 4 Example Avenue, Dallas, TX 75202. Checked by MK. Put those in as well and give me the sheet index again.

    ArchX · 2 min 33 s

    Updated and verified the existing fields on all 8 sheets for Example Duplex, including both addresses, architect, Permit Set, TG, and MK. […] Example Holdings LLC is recorded in project information but isn’t displayed by this template. Revisions remain blank; “Layouts” is unnumbered. Type “Undo” to reverse the update. Should I add a visible owner line to the title blocks?

  3. You

    Put the title blocks back the way they were.

    ArchX · 34 s

    Restored and verified the previous title-block and project-information values on all 8 sheets. The last sheet index still shows the reverted entries. Should I regenerate it to match?

ArchX, conversation “Fill Permit Set Title Blocks”: the answer to the second sentence, existing fields updated and verified on all 8 sheets, the owner recorded but not shown by the template, the offer to add an owner line, below it the sheet index as an Excel file
In ArchX: the answer to the second sentence, with the sheet index below it.

Reads what Archicad draws

Client, project, address, firm, status, drawn by, date: ArchX says field by field what is empty, also behind placeholders and the template's sample text.

Sheet list in Excel

Sheet number, title, sheet size, scale, revision and status, with the title block per sheet and the check.

Back to the value before

One sentence put all eight sheets back in 34 seconds, and ArchX checked them. In the tool test, undo put every field back to its value before. In the Swiss conversation, where ArchX had added lines for client and drawn by to two title block templates, one text block kept its changed width afterward; its content was back to the old one.

Revision and publishing

Archicad only lets you issue a revision by hand; ArchX tells you where. If you ask, ArchX also starts the publisher set. We have not seen the finished PDF yet: in demo mode, where we test, Archicad refuses to write it, and ArchX reports that within seconds.

ArchicadTemplateSheets readEmpty fields before → afterUndo
27 CHE, WindowsSchweizer Vorlage 2714 in 5.5 s18 → 328 values
28 USA, WindowsGeneric Template8 in 4.8 s14 → 118 values
29 CHE, MacBasic Vorlage8 in 11.1 s14 → 118 values
30 USA, WindowsUSA Template48 in 13.3 s12 → 027 values

The table: tool runs of November 6, 2026 in demo mode, untitled projects from the templates, without a conversation and with 15 values given; the fields set were read back without ArchX on three sheets each. Archicad 27 and 29 ran with the Tapir interface ArchX installs for a firm, 28 and 30 with our own build of it. What stays empty afterward is the revision and the firm's own fields. The conversation: November 7, 2026, in English, in the Swiss edition of Archicad 29 (Mac, demo mode), an untitled project from its Basic template, whose sheets and title block fields carry German names; with ChatGPT Pro (GPT 6.1 Sol, very high) and the code of ArchX 0.1.4; times from sending to the answer. In demo mode Archicad cannot save, so the project stayed unsaved; the first change stopped because the unsaved project could not be confirmed, and ArchX asked before trying again. That template has no title block line for the owner: ArchX recorded the owner in the project information, said so and offered to add a line. We have not seen the PDFs written in demo mode: Archicad refuses it there.

See every change first, if you want to.

By default, ArchX makes the change in Archicad directly. If you choose “Ask for approval”, you see this card before every change and approve it with Run. Then the change is in the model.

ArchX with “Ask for approval”, card “Change in Archicad”: change element properties 1 item, change doors 1 item, update rooms once, project untitled · Archicad 29; number the hall 106, widen the bath door from 28 to 36 inches; buttons No and Run; below, “Waiting for your approval”.
In ArchX with “Ask for approval”: the card before the change, with No and Run.
Archicad 29, floor plan of the test apartment with rooms, doors and windows after the change.
In Archicad: the floor plan after the change.

Screenshots of November 1, 2026: developer build of ArchX in U.S. English and Archicad 29 on a Mac, test apartment with no client data.

A two-story house in five sentences.

An empty Archicad project and five sentences, the way you’d say them in the office. Four came out done: the shell, the gable roof, a 3D check and a sheet at 1/8″ = 1′-0″. The stair did not, and ArchX said so itself. All five took 19 min 42 s.

  1. Sentence 1 · 3 min 28 s

    Two-story shell

    Build me a two-story house, 32 by 40 feet, 9-foot stories: 8-inch exterior walls, one interior partition on the first floor, a slab on grade and a second floor slab, two windows facing south on each floor and a front door on the north side.

    ArchX sets up the stories and builds eight 8″ exterior walls, one 4½″ first-floor partition, the slab on grade and the second-floor slab, four south-facing windows and the front door. What the sentence left open, it assumed and said so: 4-inch/8-inch slabs, 3′ × 5′ windows, a 3′ × 7′ door. 1,280 SF per floor; 2,560 SF total; checked by hand, 32′ × 40′ = 1,280 SF.

    ArchX with “Ask for approval”, card “Change in Archicad”: change stories 4 items, create walls 9 items, create slabs 2 items, create windows 4 items, create doors 1 item, update rooms once, project untitled · Archicad 30, with the description of the 32 by 40 foot shell.
    In ArchX with “Ask for approval”: the card before building, with every element and dimension.
    Archicad 30, 3D view of the shell as built: exterior walls, the first-floor partition, the slab and the entry door.
    In Archicad: the walls, the partition and the door, as built.
  2. Sentence 2 · 2 min 29 s

    Gable roof

    Put a gable roof on it, 8/12 pitch, ridge running the long way, and run the gable walls up to the roof.

    An 8:12 gable roof with the ridge running along the 40-foot north–south length; both gable walls now extend to the roof underside. Assumed: 12-inch overhangs and a 12-inch roof assembly.

    Archicad 30, 3D view of the two-story house with the 8:12 gable roof and the gable walls run up to it, two windows on each floor of the south gable.
    In Archicad: the house with the gable roof.
  3. Sentence 3 · 6 min 15 s

    Stair with floor opening

    Add a straight stair from the first to the second floor, 3 feet wide, with the opening in the floor.

    ArchX planned a 3-foot straight stair rising 9′ on 15 equal risers with 11″ treads and the opening in the second-floor slab, then corrected it in a second step that replaced the first stair.

    Not finished, and ArchX said so: Archicad retained 18 six-inch risers after correction, creating a 16′-6″ flight, so the floor opening still covers the upper steps. ArchX left the conflict visible in 3D instead of reporting it as done.

  4. Sentence 4 · 1 min 8 s

    3D check from the southwest

    Show me the house in 3D from the southwest and check that the windows are on the south side.

    ArchX turns the 3D view to the southwest, looks at the image itself and confirms: all four windows are on the south-facing gable wall, two on each floor.

    The 3D image ArchX made and checked: the two-story house from the southwest with its gable roof and two windows on each floor of the south gable.
    The image ArchX made in Archicad and checked itself.
  5. Sentence 5 · 6 min 22 s

    Sheet at 1/8″ = 1′-0″

    Put the first floor plan on a sheet at 1/8" = 1'-0" with the overall dimensions and room labels.

    ArchX creates sheet A-120 — First Floor Plan, a 24″ × 36″ sheet at 1/8″ = 1′-0″, with the overall dimensions 32′-0″ × 40′-0″, the labels NORTH ROOM, SOUTH ROOM, STAIR and a note on the unresolved stair opening.

    Archicad 30, layout A-120 with the first floor plan of the house at 1/8 inch to the foot, title block on the right.
    In Archicad: sheet A-120 with the first floor plan.
    ArchX, answer: created and opened A-120 First Floor Plan, a 24 by 36 inch sheet, scale 1/8 inch = 1 foot, overall dimensions 32 by 40 feet, labels North Room, South Room, Stair, a note on the unresolved stair opening.
    In ArchX: the answer with scale, dimensions and labels.

Log and screenshots of the acceptance run of November 1, 2026: developer build of ArchX with this version’s new features, Archicad 30 USA in demo mode on a Windows PC, a new, untitled project with no client data, one conversation from start to finish. The run showed a card before every change, as “Ask for approval” does today; time runs from the sentence to the finished answer, approval included.

Whole tasks on the model.

Not just single elements: ArchX takes on work that costs a firm hours, straight from the Archicad model. Acceptance run of November 1, 2026 in Archicad 29 on a test apartment.

Square footage by room

Give me the square footage of this apartment by room, as a spreadsheet.

ArchX reads every room from Archicad, totals the areas by floor and saves the room schedule as a spreadsheet. In Archicad it colors the rooms by category. Result: the six rooms total 1,034.07 SF net.

ArchX, answer: the six rooms total 1,034.07 SF net, based on Archicad’s room areas; room schedule as an Excel spreadsheet.
In ArchX: the answer with the room schedule.
Archicad 29, floor plan of the test apartment with the rooms colored by category.
In Archicad: the rooms colored by category.

Model check before the permit set

Check the model before we submit for permit: ceiling heights, light, accessible doors and room numbers.

ArchX checks heights, glazing, door widths and room numbers and marks every finding red in Archicad. Found: Bath 103 with a 28-inch door against 32 inches clear, the hall without a number, all six doors sharing one tag. The check report comes as a spreadsheet.

ArchX, model check findings: Bath 103 door 28 inches modeled width, Hall has no number, all 6 doors share one tag; IBC 2021 and 2010 ADA Standards cited.
In ArchX: the findings with the rule and the fix.
Archicad 29, floor plan of the test apartment with a finding flagged red.
In Archicad: the finding flagged red.

Doors numbered, door schedule written

Make me a door schedule and number the doors by room.

ArchX reads the doors and the rooms on both sides and numbers the doors by room: 101A to 105A for the room doors, 106A for the entry into Hall 106. The door schedule comes as a spreadsheet.

ArchX with “Ask for approval”, card “Change in Archicad”: change elements 6 items; number all 6 doors by room, 101A–105A and 106A; buttons No and Run.
In ArchX with “Ask for approval”: the card before numbering.
ArchX, answer: all six doors numbered and verified in Archicad, 101A–105A and 106A; door and window schedule as an Excel spreadsheet.
In ArchX: the answer with the door schedule.

Screenshots of the acceptance run of November 1, 2026: developer build of ArchX in U.S. English and Archicad 29 on a Mac, test apartment with no client data. Code limits such as clear widths depend on the edition your jurisdiction adopted; ArchX takes them from the conversation.

Zoning figures, a takeoff and one rating on every wall.

Four sentences about a test apartment in Archicad 28 USA: the figures for a zoning check, a takeoff by UniFormat, one fire rating on every wall, and back again. ArchX reads every change back from the model.

  1. Sentence 1 · 26 s

    FAR and lot coverage from the model

    What are the gross floor area, FAR and lot coverage? The lot is 6,000 square feet.

    1,162.5 SF gross floor area from the ground-floor slabs, FAR 0.194 and lot coverage 19.4% on the 6,000 SF lot, plus the building figures as a spreadsheet. ArchX says what these numbers are: model figures before applying local zoning exclusions, with the footprint approximated.

    ArchX, answer: the model shows 1,162.5 SF gross floor area based on the ground-floor slabs; FAR 1,162.5 ÷ 6,000 = 0.194; lot coverage 1,162.5 ÷ 6,000 × 100 = 19.4%; model figures before local zoning exclusions; spreadsheet “Building figures”.
    In ArchX: the figures with the math and as a spreadsheet.
  2. Sentence 2 · 2 min 8 s

    Takeoff by UniFormat

    Give me the quantity takeoff from the model by UniFormat.

    Sorted by UniFormat: exterior walls 8″ 1,013.03 SF, interior partitions 5″ 717.12 SF, 7 windows, 1 exterior door, 5 interior doors, floor and ceiling finishes 1,032.56 SF each, wall finishes 2,222.18 SF, as an editable spreadsheet. The slab, 1,162.50 SF, ArchX marks as provisional: use A1030 Slab on Grade if ground support is confirmed.

    ArchX, UniFormat takeoff, lower part of the table: B2020 exterior windows 7 EA, B2030 exterior doors 1 EA, C1010 interior partitions 5 inch 717.12 SF, C1020 interior doors 5 EA, C3010 wall finishes 2,222.18 SF, C3020 floor finishes 1,032.56 SF, C3030 ceiling finishes 1,032.56 SF; B1010 provisional, A1030 slab on grade if ground support is confirmed; spreadsheet “UniFormat takeoff summary”.
    In ArchX: the takeoff by UniFormat, as an editable spreadsheet.
  3. Sentence 3 · 1 min 13 s

    One fire rating on every wall

    Which walls have no fire rating yet? Make every wall 1-hour rated.

    The five 5-inch interior partitions had no rating; the four exterior walls were rated 2 hours. ArchX sets them in one step: all 9 walls now have “Fire Resistance Rating” set to “1 hour”, verified after the change and selected in Archicad. ArchX adds what it did not check: the wall assemblies themselves have not been verified for fire resistance.

    ArchX with “Ask for approval”, card “Change in Archicad”: change element properties 9 items, project untitled · Archicad 28; set all 9 walls to 1-hour fire resistance: assign the 5 unrated interior partitions and change the 4 exterior walls from 2 hours to 1 hour; buttons No and Run.
    In ArchX with “Ask for approval”: the card with all nine walls and what changes.
    Archicad 28, floor plan of the test apartment: all nine walls selected and highlighted after the change.
    In Archicad: all nine walls selected after the change.
  4. Sentence 4 · 1 min 2 s

    And back again

    Undo that.

    ArchX puts back the four values that were set before. Then the four exterior walls are restored to 2 hours.

    Only partly undone, and ArchX said so: the five partitions had no rating before and still show 1 hour. ArchX cannot clear a value in Archicad again; it selects the five walls and points to Archicad’s own Edit › Undo.

    ArchX with “Ask for approval”, card “Undo a change in Archicad”: put the values back as they were 4 items, project untitled · Archicad 28; 5 values were not set before the change set, ArchX cannot clear a value in Archicad again, Archicad’s own Undo does that; buttons No and Undo.
    In ArchX with “Ask for approval”: the card says beforehand what comes back and what does not.
    ArchX, answer: partially undone; the four exterior walls are restored to 2 hours, the five interior partitions still show 1 hour and are selected; in Archicad, Edit › Undo undoes the restoration, then the original rating change.
    In ArchX: the answer after the undo.

Log and screenshots of the acceptance run of November 1, 2026: developer build of ArchX with this version’s new features, Archicad 28 USA in demo mode on a Windows PC, test apartment with a 1,162.5 SF slab, 9 walls, 7 windows and 6 doors, no client data. Before the run, 4 of the 9 walls had a fire rating, 5 had none. The run showed a card before every change, as “Ask for approval” does today; time runs from the sentence to the finished answer, approval included.

7 sentences, all carried out correctly.

The acceptance run of October 31, 2026 in Archicad 28 (U.S. version) on a Windows PC: an empty test project and sentences as a firm would say them. It ran with a card before every change, as “Ask for approval” does today, and every card was confirmed as a person would.

  1. You

    What do I have open in Archicad right now?

    ArchX14 s

    You have an untitled, unsaved project open in Archicad 28 (USA).

    The active story is Ground Floor (story 0). The project contains three stories.

  2. You

    Draw a small house on the first floor: 32 by 24 feet outside, 2x6 exterior walls 9 feet high, a slab on grade, one room called Living inside, and a front door in the south wall.

    Card with “Ask for approval”

    Change in Archicad

    Create walls
    4 items
    Create slabs
    1 item
    Create doors
    1 item
    Create rooms
    1 item
    Change element properties
    1 item
    Update rooms
    once
    Project
    untitled · Archicad 28

    32′ × 24′ house on Ground Floor: four 9′-high 2x6 framing walls, 4″ concrete slab on grade, Living room, and centered 3′ × 6′-8″ south entrance door. ArchX then reads the created elements back; ‘undo’ removes them again.

    Confirmed

    ArchX110 s

    Built on Ground Floor and zoomed to the house:

    • 32′ × 24′ outside, with 9′-high walls modeled at 5½″ framing thickness.
    • 4″ concrete slab on grade, assumed.
    • Automatic Living room, approximately 718 SF, with 9′ height.
    • 3′ × 6′-8″ entrance door, assumed size, centered in the south wall.

    Verified the dimensions and room area in the model.

  3. You

    How big is the room, how tall is it, and how many cubic yards of wall is that?

    ArchX26 s

    From the current model:

    • Living room: 31′-1″ × 23′-1″ inside = 717.51 SF.
    • Room height: 9′-0″.
    • Four exterior walls: 16.44 cubic yards, net of the door opening.

    The wall volume represents the full 5½″-thick modeled wall bodies, rather than individual studs.

  4. You

    Make the exterior walls 10 inches thick.

    Card with “Ask for approval”

    Change in Archicad

    Change walls
    4 items
    Change doors
    1 item
    Change elements
    4 items
    Update rooms
    once
    Project
    untitled · Archicad 28

    Make all four exterior walls 10″ thick toward the interior, preserving the 32′ × 24′ outside footprint, 9′ height, centered south door, and updated Living room. ArchX then reads the changed elements back.

    Confirmed

    ArchX60 s

    All four exterior walls are now 10″ thick, preserving the 32′ × 24′ outside footprint and 9′ height.

    • Living room: 677.44 SF.
    • Net modeled wall volume: 29.47 cubic yards.

    The Living room area and stamp have been updated.

  5. You

    Put a window centered in the west wall, 4 feet wide and 5 feet tall, sill at 3 feet.

    Card with “Ask for approval”

    Change in Archicad

    Create windows
    1 item
    Update rooms
    once
    Project
    untitled · Archicad 28

    Add a 4′-wide × 5′-high window centered in the west exterior wall, with sill 3′ above Ground Floor, and update Living room quantities. ArchX then reads the created elements back; ‘undo’ removes them again.

    Confirmed

    ArchX29 s

    Added and verified a 4′-0″ × 5′-0″ casement window, centered in the west wall, with its sill 3′-0″ above the floor and head at 8′-0″. It’s selected and zoomed into view.

  6. You

    Undo that last change.

    Card with “Ask for approval”

    Undo a change in Archicad

    Delete the elements ArchX created
    1 item
    Project
    untitled · Archicad 28

    From the change set ‘Add a 4′-wide × 5′-high window centered in the west exterior wall, with sill 3′ above Ground Floor, and update Living room quantities’. Changed elements stay as they are; Archicad's own Undo brings them back.

    Confirmed

    ArchX14 s

    Undone—the west-wall window has been removed.

  7. You

    Take the house out again.

    Card with “Ask for approval”

    Change in Archicad

    Delete elements
    7 items
    Project
    untitled · Archicad 28

    Remove the house we created on Ground Floor: Living room, front door, four exterior walls, and slab on grade. The set deletes elements. Only Archicad's own Undo brings deleted elements back.

    Confirmed

    ArchX24 s

    Removed the house from Ground Floor: all four exterior walls, the slab, Living room, and front door. Verified that all seven elements are gone.

Verbatim from the log of the acceptance run of October 31, 2026: developer build of ArchX, Archicad 28.0 (U.S. version) on a Windows PC in demo mode, new untitled project. The time runs from the sentence to the finished answer, including the confirmation.

Checked by hand, not estimated.

Figures from the acceptance runs, checked against the model.

717.51SF

Living room as ArchX read it from the model: 31′-1″ × 23′-1″ inside. By hand: 31.083 ft × 23.083 ft = 717.51 SF. With 10″ walls, 30′-4″ × 22′-4″ = 677.44 SF, as ArchX reported.

Acceptance run Archicad 28 · October 31, 2026

7of 7

Sentences carried out correctly, from the first wall to taking the house out again.

Acceptance run Archicad 28 · October 31, 2026

3versions

Archicad 28, 29 and 30 tested, in the Swiss and the U.S. versions, on Mac and Windows.

Test bench · Oct 31 and Nov 1, 2026

ArchX works in Archicad on its own.

It carries out what you ask, checks the result in the model and tells you how to undo it. If you want to see every change first, choose “Ask for approval”.

You choose how much ArchX asks

With “Approve for me”, the default, and with “Full access”, ArchX makes changes in Archicad directly. With “Ask for approval”, it shows a card before every change, with the count, the project and the Archicad version; you run it or decline. You switch under “Settings” → “Files and access”.

Deletes when you ask

ArchX removes elements only when you explicitly ask it to, such as “Take the house out again”. Deleted elements come back with Archicad’s own Undo.

Checked, with the way back

After the change, ArchX reads the elements back from Archicad and checks them against your request before it reports “done”. The answer says how to undo the change: with “Undo” in the conversation or with Archicad’s own Edit › Undo.

Every change in the log

ArchX writes every change, with its date, to a log in your project folder, so the firm can see what happened and when.

Teamwork respected

ArchX does not change elements another person has reserved. It stops before anything happens.

Your project file stays with you

ArchX talks only to Archicad on your own computer. You open, save and share the project as before.

What does your firm need?

Archicad, ArchX and an AI account on the same computer. ArchX sets up the connection itself the first time.

Your firm needs

  • Archicad 28, 29 or 30 on Mac or Windows, with a project open
  • Archicad 27 on Windows works too, tested on November 4, 2026; ArchX tells you what needs Archicad 28 or later
  • The current version of ArchX on the same computer
  • A ChatGPT account per person, Plus or higher, or an API key from OpenAI, Anthropic, Google, Mistral or xAI
  • No Collaborate or Max subscription from Graphisoft
  1. 01

    Open Archicad

    Open your project in Archicad 28, 29 or 30.

  2. 02

    Ask ArchX

    Ask ArchX, for example: “What do I have open in Archicad?” Or open “Capabilities” and choose “Try it” on the first card, “Work directly in Archicad”. ArchX checks by itself whether the connection is there.

  3. 03

    Set up once

    If it is missing, ArchX downloads the free connection, checks it and installs it. Without administrator rights on Windows, ArchX puts it in your own folder and adds it to Archicad itself; if your IT blocks that, ArchX walks you through Archicad’s Add-On Manager step by step. A Mac asks only if the Archicad folder does not belong to you.

  4. 04

    Restart Archicad

    From then on, ArchX works in the open project. This is needed once per computer and Archicad version.

What ArchX does beyond the AI in Archicad.

Graphisoft is building its own AI features into Archicad. This is how they differ from ArchX, according to Graphisoft’s own help.

TopicGraphisoft’s AI in ArchicadArchX

Creating new elements

Graphisoft’s AI in ArchicadNot provided: the tools select, read and change existing elements. Deleting is not available.

ArchXWalls, slabs, roofs, doors, windows, rooms and furniture from one sentence, up to a drawing sheet at scale, checked in the model. Deleting only when you ask.

Archicad versions

Graphisoft’s AI in ArchicadAI Assistant (Beta) from Archicad 29; the tools for AI programs with Archicad 30.

ArchXArchicad 28, 29 and 30, tested on Mac and Windows.

License

Graphisoft’s AI in ArchicadThe tools for AI programs only with a Collaborate or Max subscription.

ArchXYour existing Archicad license is enough, plus the ArchX firm license.

Work outside the model

Graphisoft’s AI in ArchicadQuestions on using Archicad and on regulations; generating images.

ArchXBid leveling, permit research, minutes, drawings from scans and pay application reviews, in the same app.

Sources: Graphisoft help for Archicad 30, read on November 1, 2026: Manage BIM elements · Supported tools · AI Assistant

What would you like to know about ArchX in Archicad?

Does ArchX fill in title blocks in Archicad?

Yes, since ArchX 0.1.4. Say what goes in them: ArchX names the empty fields and asks for what is missing, fills them in on every sheet in the Layout Book, reads them back and saves the list as an Excel file. The tools were tested in Archicad 27, 28, 29 and 30. You issue the revision in Archicad by hand, and ArchX tells you where. Sheet set

Is ArchX an AI assistant for Archicad?

Yes, and it does the work itself: ArchX reads your Archicad model, takes off areas and quantities, and builds walls, slabs, roofs, doors, windows and rooms up to a drawing sheet at scale; it changes or removes walls, slabs, doors, windows and rooms when you ask and checks the result in the model. Outside the model, the same app does the rest of the desk work: tenders, minutes, drawings and documents.

Which Archicad versions does ArchX work with?

Archicad 28, 29 and 30. We have tested the Swiss and the U.S. versions, on Mac and on Windows, and Archicad 27 on Windows as well. ArchX recognizes the version and language by itself and tells you when a feature only exists in a newer Archicad version.

Does it run on Mac and Windows?

Yes. ArchX and Archicad run on the same computer, a Mac or a Windows PC. ArchX connects only to Archicad on that computer.

What does ArchX do in my model?

It reads the project, stories, elements and your selection; takes off areas, volumes and counts per story, FAR, lot coverage and a takeoff by UniFormat; builds walls, slabs, roofs, doors, windows, rooms and furniture up to a drawing sheet at scale; changes walls, slabs, doors and windows, sets one property on many elements at once, updates the rooms and shows the result in Archicad. What ArchX built itself, one sentence takes back; changed properties go back to their earlier value.

Does ArchX change my model without asking?

With “Approve for me”, the default, and with “Full access”, yes: ArchX carries out what you ask, checks the result in the model and tells you how to undo it, with “Undo” in ArchX or Archicad’s own Edit › Undo. If you choose “Ask for approval” under “Settings” → “Files and access”, ArchX shows a card before every change and carries it out only after you confirm. ArchX deletes elements only when you explicitly ask, and it asks you before it sets up the Archicad connection the first time.

What if several Archicad instances are open?

Then ArchX stays with the project you chose in the conversation and checks it before every step. If Archicad restarts or another project is opened, ArchX asks instead of carrying on in the wrong project; “Save as” does not interrupt the work. On Windows, windows and dialogs stay with the chosen Archicad instance. This is how it works since ArchX 0.1.3.

Does it work in Teamwork with BIMcloud?

Yes. In a Teamwork project, ArchX reserves the existing elements it is about to change before anything runs. If someone else has reserved one of them, ArchX stops and names that person. Archicad lets only the person who reserved an element change it.

What does my firm need?

Archicad 28, 29 or 30 (on Windows also Archicad 27) and the current version of ArchX on the same computer, plus the AI account ArchX works with anyway: a ChatGPT account per person, Plus or higher, or an API key. No Collaborate or Max subscription from Graphisoft is needed. ArchX sets up the connection itself the first time.

Is it a plugin? What gets installed?

ArchX installs a small, free Archicad add-on called Tapir. It is open source and extends the interface Archicad provides for such connections. ArchX downloads the matching version, checks it and copies it into Archicad’s add-ons folder, replacing an older version. Without administrator rights on Windows, ArchX puts the add-on in your own folder and adds it to Archicad itself (since ArchX 0.1.2). Your project files stay as they are.

Where does my model data go?

ArchX talks only to Archicad on your own computer. What it reads from the model for a task goes, like your other files, straight to the AI provider your firm chose, with no service in between and never automatically to FrontierX. Large extracts and the log of changes stay in your project folder. Your data

Does the Archicad connection cost extra?

No. It is part of ArchX and came to every firm with version 0.0.90. The ArchX firm license applies: $2,290 a year or $229 a month for the firm, including the first person. Pricing

How is this different from the AI Graphisoft builds into Archicad?

Graphisoft’s AI Assistant (Beta, from Archicad 29) answers questions about Archicad and selects elements. Its tools for AI programs come with Archicad 30 and only with a Collaborate or Max subscription, and according to Graphisoft’s help they do not create new elements. ArchX builds, changes and removes elements when you ask and checks the result in the model, from Archicad 28 and with your existing license, and does tenders, minutes and documents in the same app. See the comparison

Does ArchX work with Revit, Vectorworks or AutoCAD?

With their files: ArchX reads IFC, DXF and PDF and delivers drawings, models and quantities as files. From ArchX 0.1.13 it also works directly in running Revit on Windows and Vectorworks on Windows and, as a beta, on Mac, according to the capabilities of your edition. From ArchX 0.1.14 it also works directly in the open drawing in AutoCAD 2021 to 2027 on Windows.

Archicad and BIMcloud are trademarks of Graphisoft SE. ArchX is a product of TYTOS GmbH and is not affiliated with Graphisoft.

Your Archicad.
With ArchX in it.

Download ArchX, open a project in Archicad and ask: “What do I have open in Archicad?”